MANTA Vascular Closure Device
A new era of simplicity and
confidence in closure is here
The
MANTA Device is the first commercially available biomechanical vascular closure
device
designed
specifically for large bore femoral arterial access site closure.
Simple deployment
Addresses the challenges of large bore closure with a single easy-to-use device.
Rapid haemostasis
Reduces time to haemostasis without pre-closure, utilizing the coagulation-inducing properties of collagen for rapid haemostasis to promote vessel healing.
Reliable closure
Delivers reproducible results and helps inspire confidence in achieving successful closure.
Engineered for versatility
Available in 14 Fr. and 18 Fr., a single MANTA Device effectively closes femoral arterial access sites following the use of large bore sheaths ranging from 12 Fr. to 25 Fr. O.D.
Contraindications:
1.
Severe calcification of the access
vessel
2.
Severe peripheral artery disease
3.
Puncture in the origin of the
profundal femoral
4.
Sheath insertion in vessel other
than the femoral artery, above the inguinal ligament, or above the most
inferior border of the epigastric artery (IEA) artery
5.
Marked tortuosity of the femoral
or iliac artery
6.
Marked obesity or cachexia (BMI
>40 or <20)
7.
Blood pressure >180 mmHg
8.
Patients who cannot be
anti-coagulated for the procedure
Warnings: Do not use:
1.
If bacterial contamination of
procedure sheath or surrounding tissues may have occurred.
2.
If the procedure sheath has been placed
through the superficial femoral artery and into the profunda femoris artery.
3.
If the MANTA Device delivery
system becomes kinked
4.
with a contralateral
balloon inflated in the femoral or iliac artery during MANTA device use
5.
If there has been a femoral artery
puncture in same vessel within prior 30 days, recent femoral artery puncture in
same groin that has not healed appropriately, and/or recent (<30 days)
vascular closure device placement in same femoral artery.
6.
If puncture site is at or distal
to bifurcation of superficial femoral and profunda femoris artery.
7.
If the puncture site is proximal to
inguinal ligament or above most inferior border of epigastric artery (IEA).
Potential Adverse Events:
1.
Failed hemostasis requiring manual
or mechanical compression, application of balloon pressure from a secondary
access site, placement of a covered stent or surgical repair.
2.
Local trauma to the femoral or
iliac artery wall, such as dissection.
3.
Retroperitoneal bleeding as a
result of access above the inguinal ligament or the most inferior border of the
epigastric artery (IEA).
4.
Perforation of ileofemoral
arteries, causing bleeding/hemorrhage.
5.
Accidental positioning of some or
all of the collagen plug within the femoral artery, leading to ischemia or
stenosis.
6.
Thrombosis formation or embolism.
7.
Nerve damage or neuropathy.
8.
Other access site complications
leading to bleeding, hematoma, pseudoaneurysm, etc., possibly requiring blood
transfusion, surgical repair, and/or endovascular intervention.
The Manta Vascular Closure Device
| SIZE |
DESCRIPTION |
.REF |
| 14Fr. |
14Fr.MANTA Vascular Closure Device |
2156NE |
| 18Fr. |
18Fr.MANTA Vascular Closure Devic |
2115NE |
| 8Fr. |
MANTA 8 Fr. Depth Locator |
188F |
| 14Fr. |
MANTA 14 Fr. Depth Locator |
114F |